<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40601</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Timeout, TEB did not trigger sensors
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The teb has had a timeout trying to accomplish it's current task.
Either the both sensors has not been tripped, or the TEB has not moved. If
the bender has moved then check for a bad sensor, otherwise check to make sure
that the TEB solenoid is working.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Make sure the air supply is on, and that the TEB initialized properly.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The following could cause this error:
TEB being blocked by some external part
bad sensors
improper air supplied to the machine
missing cable to solenoid block
bad bender solenoid
door loop not closed or overidden
abort switch is on
PS2 power not on
</Cause>
<LastModified>
08-JAN-2001
Automated conversion to new FW1 error template.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:28 2008 PST
</Updated>
<Links>
</Links>
</Error>